Print Page
The Chute Doctor, The Right Prescription for Your Trash and Laundy Chutes
“W” Series twelve inch by fifteen inch foot operated bottom hinged chute intake door with one twenty volt electrical interlock
“W” Series twelve inch by fifteen inch foot operated bottom hinged chute intake door with one twenty volt electrical interlock

SKU: 500996
Regular Price: $1,888.93
Patient Regular Price: $1,794.48
Special Order Product
12"x15" Foot Operated, Bottom Hinged Chute Intake Door Assembly with 120vac Electrical Interlock, "W" Series
12"w x 15"h Bottom hinged, foot operated, self-closing, positive latching, chute intake door assembly complete with 120vac electrical interlock. Door bears a UL label with a clear listing of 1-1/2 hour, 30 minute - 250 degree max temperature rise. Includes replaceable foot pedal, enclosed door closer, 1/2” shaft hinge with bronze bearings, removable door panel and stainless steel trim. Door Panel made with 20 gauge type 304 stainless steel front with No. 4 finish and 18 gauge satin coat galvannealed steel back. The door closer is mounted outside to the trash opening in a fully enclosed heavy duty box accessible from the front to ensure years of trouble free operation. Stainless Steel trim available blank or embossed with "Rubbish", "Soiled Linen", or "Recycle".

Includes a 120vac electrical interlock with push button and in-use indicator light. Interlocks allow only one door open at a time to reduce clogging and enhance safety during peak usage periods. User must unlock the door by pressing the foot pedal. Interlocks are designed to be normally locked so that in a power failure doors can not be opened. This also allows all doors to be locked out by turning off the power switch when working beneath the chute, greatly reducing liability and injuries.

Our 120vac Electrical interlocked chute intake doors are engineered for use on 120vac 60hz line voltage therefore the intake door electrical panels and components are UL listed. Wiring is to be in conduit in most applications. Check with your local building authority regarding installation requirements. Requires basic or programmable control and power supply for operation.

A direct replacement for Wilkinson Chutes Canada and Chute Source #W-7 with interlocks (seven wire system) and replaces easily with minimal wall repair. Can be retrofitted to others chutes with sheet metal adaptors and wall modifications to fit chute door openings for doors of the same size. However, interlock compatibility must be determined prior to ordering as a replacement. Complies with building codes, NFPA-82 and ASTM standards. Made in Canada by Union Craftsmen.

Chute Doctor Keeping Your Chute Healthy™

California License #767939; Arizona License #ROC149925

“W” Series twelve inch by fifteen inch foot operated bottom hinged chute intake door with one twenty volt electrical interlock
“W” Series twelve inch by fifteen inch foot operated bottom hinged chute intake door with one twenty volt electrical interlock

Recently Viewed

12"x15" Foot Operated, Bottom Hinged Chute Intake Door Assembly with 120vac Electrical Interlock, "W" Series

12"w x 15"h Bottom hinged, foot operated, self-closing, positive latching, chute intake door assembly complete with 120vac electrical interlock. Door bears a UL label with a clear listing of 1-1/2 hour, 30 minute - 250 degree max temperature rise. Includes replaceable foot pedal, enclosed door closer, 1/2” shaft hinge with bronze bearings, removable door panel and stainless steel trim. Door Panel made with 20 gauge type 304 stainless steel front with No. 4 finish and 18 gauge satin coat galvannealed steel back. The door closer is mounted outside to the trash opening in a fully enclosed heavy duty box accessible from the front to ensure years of trouble free operation. Stainless Steel trim available blank or embossed with "Rubbish", "Soiled Linen", or "Recycle".

Includes a 120vac electrical interlock with push button and in-use indicator light. Interlocks allow only one door open at a time to reduce clogging and enhance safety during peak usage periods. User must unlock the door by pressing the foot pedal. Interlocks are designed to be normally locked so that in a power failure doors can not be opened. This also allows all doors to be locked out by turning off the power switch when working beneath the chute, greatly reducing liability and injuries.

Our 120vac Electrical interlocked chute intake doors are engineered for use on 120vac 60hz line voltage therefore the intake door electrical panels and components are UL listed. Wiring is to be in conduit in most applications. Check with your local building authority regarding installation requirements. Requires basic or programmable control and power supply for operation.

A direct replacement for Wilkinson Chutes Canada and Chute Source #W-7 with interlocks (seven wire system) and replaces easily with minimal wall repair. Can be retrofitted to others chutes with sheet metal adaptors and wall modifications to fit chute door openings for doors of the same size. However, interlock compatibility must be determined prior to ordering as a replacement. Complies with building codes, NFPA-82 and ASTM standards. Made in Canada by Union Craftsmen.
SKU: 500996
Regular Price: $1,888.93
Patient Regular Price: $1,794.48Want a better price?
Quantity:    
Special Order ProductHelp
See Quantity Discounts
Installation available for this item! Please enter your zip code to see if we provide service in your area:
Property Zip Code
Check Availability and Pricing

Related Products

Related Search Terms

Schute Doors, BHHO door, Shoot door, chute access door, chute inlet door, chute outlet door, garbage chute, waste, electric lock out, limited access, remote control, NFPA, Chute-Type fire Door, GSPR, UL, Underwriters Laboratories, WB1818EI, W-7, R26294, R9420, R25541, R20481, R18916, R16698, R21689, R7351, R15927, R13884, R25465, R6855, R26072, R15889, R21753, R2071, R4618, R19146, R16492, R3542, R18123, R25539